USP Prolink 1.2kva Pro1201sfc
Capacity
1200VA
Input
Voltage Range
140 – 300V ± 5%
Frequency
50Hz/60Hz (Auto-sensing)
Phase
Single + GND
Output
Voltage Range
230VAC +12% -14%
Battery Mode
230VAC +10% -10%
Frequency
50Hz ± 1% (Battery Mode)
Waveform
– Simulated Sine Wave (Battery Mode)
– Sine Wave (AC Mode)
Battery Type
12V/8.2AH – 2pcs
Backup Time
8 – 30 minutes depending on load
Recharge Time
2 – 4 hours recover to 90% capacity
Protection / Monitoring
Short Circuit Protection
Yes (Line Mode and Battery Mode)
Surge Protection
Yes
Alarm
Audible & Visual
UPS Protection
Load auto sensing and abnormal protection
Overload Protection
– Line mode : 100 – 120% 5 mins change to fault mode >120% change to fault mode shutdown immediately
– Battery mode : 100 – 110% alarm & shutdown in 10 secs >120% shutdown immediately
Intelligent Battery Management
Prevent overcharging of battery
Protect battery and prolong battery life
General
Software
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix, and Mac
Noise Level
<40dB
Temperature
0°C – 40°C
Humidity
0 – 90%
Power Factor
Up to 0.7
Built in AVR
TRUE Full AVR (3 steps)
Product Specifications
- – Boost and buck AVR for voltage stabilization
- – Auto restart while AC is recovering
- – Simulated sine wave
- – Off-mode charging
- – Cold start function
0 customer review
Sorry, There are no reviews here !

Laptop.lk
Welcome to Laptop.lk, your online portal to the world of laptops and technology.

Laptop.lk
Welcome to Laptop.lk, your online portal to the world of laptops and technology.
Capacity
1200VA
Input
Voltage Range
140 – 300V ± 5%
Frequency
50Hz/60Hz (Auto-sensing)
Phase
Single + GND
Output
Voltage Range
230VAC +12% -14%
Battery Mode
230VAC +10% -10%
Frequency
50Hz ± 1% (Battery Mode)
Waveform
– Simulated Sine Wave (Battery Mode)
– Sine Wave (AC Mode)
Battery Type
12V/8.2AH – 2pcs
Backup Time
8 – 30 minutes depending on load
Recharge Time
2 – 4 hours recover to 90% capacity
Protection / Monitoring
Short Circuit Protection
Yes (Line Mode and Battery Mode)
Surge Protection
Yes
Alarm
Audible & Visual
UPS Protection
Load auto sensing and abnormal protection
Overload Protection
– Line mode : 100 – 120% 5 mins change to fault mode >120% change to fault mode shutdown immediately
– Battery mode : 100 – 110% alarm & shutdown in 10 secs >120% shutdown immediately
Intelligent Battery Management
Prevent overcharging of battery
Protect battery and prolong battery life
General
Software
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix, and Mac
Noise Level
<40dB
Temperature
0°C – 40°C
Humidity
0 – 90%
Power Factor
Up to 0.7
Built in AVR
TRUE Full AVR (3 steps)
Product Specifications
- – Boost and buck AVR for voltage stabilization
- – Auto restart while AC is recovering
- – Simulated sine wave
- – Off-mode charging
- – Cold start function